Siemens EuroSetline Series
Default serial communications settings for EuroSetline 8i, EuroSetline 16, EuroSetline 16i and EuroSetline 48i:
| Default configuration | |
|---|---|
| baud rate | 9600 |
| data bits | 8 |
| parity | none |
| stop bits | 1 |
| flow control | hardware |
Siemens Hicom 100 Series
Hicom 100, Hicom 110, Hicom 120
With PCSAT software:
- Data for Call-Duration Recording
- Line-Related Data for CDR
- Outgoing Calls: Y
- Incoming Calls: Y
- Account Codes: Y
- Data Mode Intervals: Y
- System Data for Printer and Interface
- Followed by blank lines: N
- Lines per page: 00
- Data records per page: 00
- Control characters preceding records: – -
- Control characters following records: CR LF
- CDR Data Record
- Set elements to one of the following configurations:
- DT TI DU ST CN CH EN
- DT TI DU ST CN CH CI EN
- Set elements to one of the following configurations:
Siemens Hicom 150 Series
Informations from this page are valid for all models including: Hicom 150, Hicom 150 E (150E), Hicom 150 H OfficePoint, Hicom 150 H OfficePro, Hicom 150 H OfficeCom.
In OfficeCom OfficePoint, the V24/2 module provides two serial V.24 (RS-232) interfaces for connecting a PC, a printer, or Plus Products (such as Uniform Call Distribution). The V24/1 (not for U.S.) is an under equipped version with only one V.24 (RS-232) interface.
Interfaces: V24 Interfaces (S30807-Q6916-Xxxx) Note: We recommend setting up call detail recording central (CDRC) on interface X2 of OfficeCom and OfficePoint (software configuration required) if a V24/2 module is installed.
Use a shielded 9-pin cable as a connecting cable. The wires must be twisted and have a diameter of at least 0.5 mm (24 AWG). The integrated wire shielding must be soldered onto the connector and socket housing of both cable ends. Short-haul modems must be provided if the cable length exceeds 15 m (50 ft.).
Pin Assignment of the 9-Pin Socket and 25-pin Connector on the V.24 (RS-232) Cable for OfficePro 9-Pin Sub-D Socket 25-Pin Sub-D Connector Signal 1 8 DCD (Data Carrier Detect) 2 3 RxD (Receive Data) 3 2 TxD (Transmit Data) 4 20 DTR (Data Terminal Ready) 5 7 GND (Signal Ground) 6 6 DSR (Data Set Ready) 7 4 RTS (Request To Send) 8 5 CTS (Clear To Send) 9 22 RI (Ring Indicator)
Cable V24/1 (Not for U.S.) and V24/2
Connector Assignment V.24 (RS-232) Contact Assignments, OfficeCom and OfficePoint
Siemens Hipath 1100 Series
The current settings were tested with Siemens Hipath 1100, Siemens Hipath 1120, Siemens Hipath 1150, Siemens Hipath 1220, Siemens Hipath 1190.
In order to configure PbxMon to capture data using TCP/IP from a Hipath 1100 Series (like Hipath 1150 or Hipath 1190) please choose as pbx driver Siemens Hipath 1190 binary/CommServer.
At log server address write the IP of the PBX and the port 3118. For example if your PBX has the IP 192.168.6.66 you will have to write 192.168.6.66:3118
Siemens Hipath 3000 Series
Activating call accounting for Siemens Hipath 3000 Series.
This article is valid at least for
- Siemens Hipath 3000
- Siemens Hipath 3350
- Siemens Hipath 3500
- Siemens Hipath 3750
- Siemens Hipath 3800
Default parameters for serial communication: 9600-8-N-1 with hardware Flow Control: Now you have to setup the PBX using a programming software, like HiPath 3000 Manager.
PbxMon Configuration
In Pbxmon select Siemens Hipath 3000 Series (recommended). This will use Uncompressed (Decimal on). If you do not see this option please install the latest update.
Pbx Configuration
- Output format
* [ ] Compressed format * [ ] Last 4 digits surpressed * [x] Log incomming calls * [x] Call Duration * [ ] On Ringing * [x] Output MSN * [x] Decimal format * [ ] Display amounts instead of units
Pin assignment (wiring) for HiPath 3000
PC PBX (9 PIN) (9 PIN) 1 1 2 3 3 2 4 6 5 5 6 4 7 8 8 7 9 9